Roof and pipe heat cables

Heat cable keeps a path open for meltwater on the roof, or keeps a vulnerable pipe above freezing through a cold snap.

Compare side by side

Roof and pipe heat cables compared. Best in each row is shaded, bold and ticked
Specification Best roof and gutter kit Frost King Electric Roof Cable Kit, 60 ft Best for metal roofs Raychem FrostGuard 120 V Self-Regulating Heating Cable, 50 ft Best pipe cable with thermostat Frost King Automatic Electric Heat Cable Kit for pipes, 6 ft Best self-regulating pipe cable Raychem FrostGuard 120 V Self-Regulating Pipe Heating Cable, 6 ft
Our score Our score: 7.0 out of 10 Our score: 7.8 out of 10 Our score: 7.2 out of 10 Our score: 7.9 out of 10(best in this row)
Use Roof, gutters and downspouts Pipes, roof and gutters Water pipes Pipes, roof and gutters
Cable type Constant wattage Self-regulating Constant wattage Self-regulating
Cable length 60 ft 50 ft 6 ft 6 ft
Output 5 W/ft 8 W/ft 7 W/ft 6 W/ft
Thermostat None built in; Frost King sells the RSC2 plug-in thermostat None needed (self-regulating cable) Built in: on below about 38 °F, off above 45 °F None needed (self-regulating cable)
Pipe types not listed Metal or plastic water pipe, not garden hose Metal or Schedule 40 plastic supply pipe, 3/8 in to 1 1/2 in OD Metal or plastic water pipe, not flexible vinyl tubing
Roof types Inclined asphalt-shingle roofs; metal or plastic gutters and downspouts Shingle, shake, rubber, tar, wood, metal and plastic roofs; metal or plastic gutters not listed not listed
Ground-fault protection Needs a GFCI-protected outlet Needs a GFCI-protected outlet not listed Needs a GFCI-protected outlet
Where to buy

Before you buy

  • Match the use Roof cable and pipe cable are different products; check the maker allows your pipe material and roof type.
  • Use a GFCI outlet The US CPSC says heat tape belongs on a grounded, GFCI-protected outlet, and Raychem requires ground-fault protection on every circuit.
  • Inspect each fall Look for cracked insulation or bare wire before the cold arrives, and replace old uncertified tape.

Need your driveway or roof cleared of snow?

Pick the job, then your city.

We don’t store what you type.

See every trade we list

Heat cable questions

Does heat cable need a GFCI outlet?

Yes. The US CPSC says to plug heat tape into a grounded, GFCI-protected outlet. Raychem’s FrostGuard data sheet requires ground-fault protection on every circuit, because an ordinary breaker may not stop arcing in a damaged cable. No extension cords.

Can heat cable go on any roof?

No. Frost King’s roof cable instructions rule out wood shingles, rubber or membrane roofs, tar and gravel, flat roofs and wooden gutters. Raychem’s self-regulating FrostGuard is approved on more roof types, including metal. Check the maker’s list for yours.

Can heat cable overlap itself?

Constant-wattage cable, no: Frost King says never to cross or double it, as it can overheat. Raychem says its self-regulating cable can’t overheat where runs touch, but still follow its installation manual. The CPSC suggests inspecting tape each fall.